R1 Cartridge BiOptic

RNA Cartridges

PRODUCTS

RNA Cartridges

RNA Cartridges

R1 RNA Cartridge Kit

  1. The cartridge is ideal for low concentration RNA analysis and the analysis time is between 5~7 minutes.
  2. The system provides RNA Quality Number (RQN) for total RNA integrity reference.
  3. Each cartridge can analyze 100 runs for single-channel cartridge or 400 runs for 4-channel cartridge.
  4. The cartridge can be stored at room temperature (15~27°C) and is valid for 4 months.
R1 Cartridge BiOptic

NR1 High Sensitivity RNA Cartridge Kit

  1. The cartridge is ideal for low concentration RNA analysis (LOD 1 ng/μl) and the analysis time is between 5~7 minutes.
  2. The system provides RNA Quality Number (RQN) for total RNA integrity reference.
  3. Each cartridge can analyze 100 runs for single-channel cartridge or 400 runs for 4-channel cartridge.
  4. The cartridge can be stored at room temperature (15~27°C) and is valid for 4 months.
NR1 Cartridge BiOptic
Ready To Order?
Our team can help you in placing the order. Click below to get a quote and fast ordering.
BiOptic Consumables Portfolio

Have a question?

Get a call from your local Decode Science representative to help you find the best fit genomics products for you.

    Or give us a call at:

    1300 581 991

    High Resolution Quantitative Cartridge Kit BiOptic

    Quantification Kit

    PRODUCTS

    Quantitative Kit

    Quantitative Kit

    S2 Standard Quantitative Cartridge Kit

    1. The fragment sizes and relatively accurate quantitative results can be obtained simultaneously. Extra time and cost for quantitative analysis can be saved.
    2. S2 cartridge is for PCR products, small-sized DNA, and NGS quality control (Fragmentation and Library sample) analyses.
    3. The analysis time is about 3 minutes, and the best resolution is 4~10bp if the sample size is less than 500bp.
    4. Each cartridge can analyze 200 runs for single-channel cartridge or 800 runs for 4-channel cartridge.
    5. The cartridge can be stored at 4~27°C and is valid for 6 months.
    Standard Quantitative Cartridge Kit BiOptic

    S1 High Resolution Quantitative Cartridge Kit

    1. The fragment sizes and relatively accurate quantitative results can be obtained simultaneously. Extra time and cost for quantitative analysis can be saved.
    2. Not only the total concentration but also the individual fragment concentration can be provided.
    3. The analysis time is about 3~5 minutes, and the best resolution is 1~4bp if the sample size is less than 500bp.
    4. Each cartridge can analyze 200 runs for single-channel cartridge or 800 runs for 4-channel cartridge.
    5. The cartridge can be stored at 4~27°C and is valid for 6 months.
    High Resolution Quantitative Cartridge Kit BiOptic

    N1 High Sensitivity Quantitative Cartridge Kit

    1. The fragment sizes and relatively accurate quantitative results of low concentration DNA can be obtained simultaneously with individual fragment concentration provided.
    2. The applications include low concentration DNA fragments and cell-free DNA quality control.
    3. The analysis takes about 3 minutes with a recommended size range up to around 5,000bp and a detection limit of about 10 pg/μl.
    4. Each cartridge can analyze 100 runs for single-channel cartridge or 400 runs for 4-channel cartridge.
    5. The cartridge can be stored at 4~27°C and is valid for 4 months.
    Ready To Order?
    Our team can help you in placing the order. Click below to get a quote and fast ordering.
    BiOptic Consumables Portfolio

    Have a question?

    Get a call from your local Decode Science representative to help you find the best fit genomics products for you.

      Or give us a call at:

      1300 581 991

      P2 Cartridge BiOptic

      Protein Cartridges

      PRODUCTS

      Protein Cartridges

      Protein Cartridges

      P2 Protein Cartridge Kit

      1. The cartridge analyzes protein sample size and purity with higher sensitivity and resolution.
      2. The analysis size range is 11~155kDa but the detection range is up to 600kDa.
      3. Qsep100 Advance is the recommended platform for detecting fluorescent-labeled protein sample.
      4. Each cartridge can analyze 100 runs for single-channel cartridge or 400 runs for 4-channel cartridge.
      P2 Cartridge BiOptic
      Ready To Order?
      Our team can help you in placing the order. Click below to get a quote and fast ordering.
      BiOptic Consumables Portfolio

      Have a question?

      Get a call from your local Decode Science representative to help you find the best fit genomics products for you.

        Or give us a call at:

        1300 581 991

        S2 Cartridge (Standard Cartridge) BiOptic

        DNA Cartridges

        PRODUCTS

        DNA Cartridges

        DNA Cartridges

        S2 Standard Cartridge Kit

        1. S2 cartridge is for PCR products, small-sized DNA, and NGS quality control (Fragmentation and Library sample) analyses.
        2. The analysis time is 2~3 minutes and the best resolution is 4~10bp if the sample size is less than 500bp.
        3. It has a recommended size range up to around 5,000bp and a detection limit of about 0.1 ng/μl in low concentration.
        4. Each cartridge can analyze 200 runs for single-channel cartridge or 800 runs for 4-channel cartridge.
        5. The cartridge can be stored at 4~27°C and is valid for 6 months.
        S2 Cartridge (Standard Cartridge) BiOptic

        S1 High Resolution Cartridge Kit

        1. The analysis time is 2~5 minutes and the best resolution is 1~4bp if the sample size is less than 500bp.
        2. It provides high resolution result with multiple methods from low to high voltage (2~10kV) for user to choose from.
        3. It has a recommended analysis range up to around 5,000bp and a detection limit of about 0.1 ng/μl in low concentration.
        4. Each cartridge can analyze 200 runs for single-channel cartridge or 800 runs for 4-channel cartridge.
        5. The cartridge can be stored at 4~27°C and is valid for 6 months.
        S1 Cartridge BiOptic

        S3 Kilobase Cartridge Kit

        1. S3 cartridge is for large-sized DNA analysis.
        2. It has a recommended 5~165kb size range and is ideal for quality control of second and third generation sequencing.
        3. The system provides DNA Quality Number (DQN) for gDNA integrity reference.
        4. Each cartridge can analyze 200 runs for single-channel cartridge or 800 runs for 4-channel cartridge.
        5. The cartridge can be stored at 4~27°C and is valid for 6 months.
        S3 Cartridge BiOptic

        F3 Fast Cartridge Kit

        1. The analysis time is 90 seconds and can be applied to PCR product analysis.
        2. It has a recommended analysis range up to around 5,000bp for DNA.
        3. It runs on Qsep100 and Qsep400 only.
        4. Each cartridge can analyze 300 runs for single-channel cartridge or 1200 runs for 4-channel cartridge.
        5. The cartridge can be stored at 4~27°C and is valid for 4 months.
        F3 Cartridge BiOptic

        N1 High Sensitivity Cartridge Kit

        1. The sample concentration for analysis has a detection limit of about 5 pg/μl (or 1 pg/μl if dissolved in ddH2O) and the analysis time is about 3 minutes.
        2. It can be used for analysis of low concentration DNA fragment and quality control of cell-free DNA.
        3. It has a recommended analysis range up to around 5,000bp for DNA.
        4. Each cartridge can analyze 100 runs for single-channel cartridge or 400 runs for 4-channel cartridge.
        5. The cartridge can be stored at 4~27°C and is valid for 4 months.
        N1 Cartridge BiOptic

        N3 High Sensitivity Kilobase Cartridge Kit

        1. N3 cartridge is for low concentration large-sized DNA analysis.
        2. It has a recommended 5~165kb size range and is ideal for quality control of second and third generation sequencing.
        3. The system provides DNA Quality Number (DQN) for gDNA integrity reference.
        4. Each cartridge can analyze 200 runs for single-channel cartridge or 800 runs for 4-channel cartridge.
        5. The cartridge can be stored at 4~27°C and is valid for 4 months.
        N3 Cartridge BiOptic